Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • February 2011 • Rev B Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1, 2, 12, 44 Covers to blue color, TurollaOCG brand name, Biofluids deleted. B Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical…
Dateityp: application/pdf
Verlinkt bei:
Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • February 2011 • Rev B Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1, 2, 12, 44 Covers to blue color, TurollaOCG brand name, Biofluids deleted. B Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical…
Dateityp: application/pdf
Verlinkt bei:
Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • June 2010 • Rev A Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
Group 2 Gear Pumps Technical Information OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ 2 OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP ™ L1016341 • June 2010 • Rev A Group 2 Gear Pumps Technical Information Table of revisions Date Page Changed Rev. 28, June 2010 - First edition A Literature reference for gear products Title Type Order number General Aluminum Gear Pumps and Motors Technical Information L1016238 Group 1 Gear Pumps Technical Information L1016399 Group 3 Gear Pumps Technical Information L1016456 Group 1, 2 and 3 Gear Motors Technical Information L1016082 Hydraulic Fluids…
Dateityp: application/pdf
Verlinkt bei:
HC3- H miniBOOSTER Description The HC3 - H is a variant of the HC3 with the topside and the B port closed, not needing a top plate. It is designed for use in NG6 (D03) stacking manifold systems. Like the other HC3 units, the HC3- H is a compact unit. The HC3 has the pilot- operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2…
Dateityp: application/pdf
Verlinkt bei:
HC3- H miniBOOSTER Description The HC3 - H is a variant of the HC3 with the topside and the B port closed, not needing a top plate. It is designed for use in NG6 (D03) stacking manifold systems. Like the other HC3 units, the HC3- H is a compact unit. The HC3 has the pilot- operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/ min 1.2 1.2 8.0 1.5 1.0 8.0 2.0 2.0 12.0 2.8 2.2…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC6DHW Description The HC6DHW is a high flow dual- acting stainless steel 316 L unit which is capable of delivering up to 12.5 l/ min flow on the high- pressure end. Like other miniBOOSTER models, the HC6DHW raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6DHW is a compact unit weighing 35.0 kg. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/…
Dateityp: application/pdf
Verlinkt bei:
miniBOOSTER HC6DHW Description The HC6DHW is a high flow dual- acting stainless steel 316 L unit which is capable of delivering up to 12.5 l/ min flow on the high- pressure end. Like other miniBOOSTER models, the HC6DHW raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6DHW is a compact unit weighing 35.0 kg. Flow rates Intensification factor i Max. outlet flow l/ min Max. inlet flow l/…
Dateityp: application/pdf
Verlinkt bei:
GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information Orange - CMYK 99%Y 76%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y D SERIES GEAR MOTORS I TECHNICAL INFORMATION2 Turolla - L1022895 • April 2018 • Rev H History of revisions Date Page Changed Rev. Feb. 2009 - First edition AA Nov. 2009 25 TY shaft uses a #8 woodruff key AB Feb. 2010 last Fix Osaka address AC April 2010 various Add reversing fan drive motor BA Nov. 2010 all Turolla colors CA July 2011 all Turolla new layout, fonts update, Sauer-Danfoss replacement. D October 2011 1 Cover page change E…
Dateityp: application/pdf
Verlinkt bei:
GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information Orange - CMYK 99%Y 76%M Grey - CMYK 44% Black 77C 33M 55K 50C 100Y 66M 88Y 66M 88Y D SERIES GEAR MOTORS I TECHNICAL INFORMATION2 Turolla - L1022895 • April 2018 • Rev H History of revisions Date Page Changed Rev. Feb. 2009 - First edition AA Nov. 2009 25 TY shaft uses a #8 woodruff key AB Feb. 2010 last Fix Osaka address AC April 2010 various Add reversing fan drive motor BA Nov. 2010 all Turolla colors CA July 2011 all Turolla new layout, fonts update, Sauer-Danfoss replacement. D October 2011 1 Cover page change E…
Dateityp: application/pdf
Verlinkt bei: